Chilled Water Pipe Size Chart Ashrae
Outside radius of pipe in t insulation thickness listed in this table for applicable fluid temperature and pipe size.
Chilled water pipe size chart ashrae. Hvac selection based on frictional loss of 4 ft of water 100 ft pipe dia 4 inches pipe size max flow ton of refrigeration velocity inches mm us gpm 2 4 ogpm tr t 10of 2 67 gpm tr t 9f fps m s 12 2 0 7 0 7 1 9 0 6. Chilled water brine and refrigerant d. 1 4 ft friction loss per 100 ft of pipe. If you reduce air and turbulence you can exceed the 4 ft limit.
Ashrae sdl course on chilled water plant. Water pipe sizing excel calculator for hvac chilled water systems is submitted below download it for free. For greater than 2 dia keep pd 4 ft per 100 ft pipe. Of course the same pipe sizing requirements of ashrare 90 1 discussed above are also included in ashrae 189 1.
For noise keep velocity less than 4 feet per second fps for 2 dia. Download chilled water system pipe sizing excel sheet spreadsheet calculator for sizing hvac chiller systems pipes. Kw rt is function of flow per rt and head. M per 30 m of pipe water velocity e g 10 fps 3 0 m s or a combination about the author steven t.
For more information about pipe sizing for water distriibution call the advantage sales department at 317 887 0729. 2 5 ft as mean. Chilled water pump. Ashrae 2001 fundamentals ch.
Taylor p e fellow ashrae optimizing design control of chilled water plants part 3. Carrier hap 5 1. Taylor p e is a principal at taylor engi neering in alameda calif. 1 4 components and layouts of central chilled water system 12 1 5 measurement and calculation of chilled water system performance 16 1 6 measurement and instrumentation requirements 24 1 7 chiller performance based on iplv nplv and singapore standards 27 1 8 optimisation of chilled water system 30.
B g system syzer is ashrae 90 1 and 189 1 compliant it may seem as though ashrae just made engineers jobs more difficult but jmp has good news for those who haven t the time or the practice to perform the piping calculations required to meet ashare 90 1. Chilled water piping distribution systems ashrae 3 12 14. Using same pipe size kw rt drops from 0 058 to 0 018 additionally ct performance improves with larger range dt. Available for free download.
Pipe sizing and optimizing. Chilled water piping system types typical configuration load. Edrc std h pd 001 chilled water pipe sizing discipline. By varying flow of water in coils per chiller system load 50 tons 176kw 50tons 176 kw primary bypass flow 250 gpm 95 l s 150 gpm 9 5 l s.
Download ashrae heat load calculation excel sheet xls.